Micro electric cylinder | High precision electric slide
The ELS series of miniature electric desktop cylinders have the characteristics of high energy density, large load capacity, and compact design. It can be applied in various application scenarios to complete complex tasks such as pick and place, arrangement and processing.
-
Integrated Drive and Control
-
Direct Drive Closed-Loop Control Technology
-
Ultra Thin Size
ELS series
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Model |
ELS-SW |
ELS-SW |
ELS-SW |
ELS-30 |
ELS-30 |
ELS-30 |
ELS-50 |
ELS-50 |
ELS-50 |
Total Travel |
30,50mm |
30,50mm |
30,50mm |
30mm |
30mm |
30mm |
50mm |
50mm |
50mm |
Lead of lead screw mm |
2mm |
4mm |
6mm |
2mm |
4mm |
6mm |
2mm |
4mm |
6mm |
Rated thrust N |
100N |
50N |
30N |
100N |
50N |
30N |
100N |
50N |
30N |
Minimum thrust N |
30N |
15N |
9N |
30N |
15N |
9N |
30N |
15N |
9N |
Maximum speed mm/s |
100mm/s |
200mm/s |
300mm/s |
100mm/s |
200mm/s |
300mm/s |
100mm/s |
200mm/s |
300mm/s |
Maximum acceleration G |
0.3 |
0.3 |
0.3 |
0.3 |
0.3 |
0.3 |
0.3 |
0.3 |
0.3 |
Maximum Portable Weight - Horizontal kg |
6kg |
3kg |
2kg |
6kg |
3kg |
2kg |
6kg |
3kg |
2kg |
Maximum Portable Weight - Vertical kg |
1.5kg |
0.75kg |
0.5kg |
1.5kg |
0.75kg |
0.5kg |
1.5kg |
0.75kg |
0.5kg |
Position repetition accuracy mm |
±0.02mm |
±0.02mm |
±0.02mm |
±0.02mm |
±0.02mm |
±0.02mm |
±0.02mm |
±0.02mm |
±0.02mm |
Body width mm |
36mm |
36mm |
36mm |
45mm |
45mm |
45mm |
45mm |
45mm |
45mm |
Function Description |
Position mode/Push mode |
Position mode/Push mode |
Position mode/Push mode |
Position mode/Push mode |
Position mode/Push mode |
Position mode/Push mode |
Position mode/Push mode |
Position mode/Push mode |
Position mode/Push mode |
Communication protocol |
Built in: Modbus RTU (RS485) Digital I/O, IO link optional |
Built in: Modbus RTU (RS485) Digital I/O, IO link optional |
Built in: Modbus RTU (RS485) Digital I/O, IO link optional |
Built in: Modbus RTU (RS485) Digital I/O, IO link optional |
Built in: Modbus RTU (RS485) Digital I/O, IO link optional |
Built in: Modbus RTU (RS485) Digital I/O, IO link optional |
Built in: Modbus RTU (RS485) Digital I/O, IO link optional |
Built in: Modbus RTU (RS485) Digital I/O, IO link optional |
Built in: Modbus RTU (RS485) Digital I/O, IO link optional |
Recommended usage environment |
0~40°C,<85% RH |
0~40°C,<85% RH |
0~40°C,<85% RH |
0~40°C,<85% RH |
0~40°C,<85% RH |
0~40°C,<85% RH |
0~40°C,<85% RH |
0~40°C,<85% RH |
0~40°C,<85% RH |
Interface cable outlet method |
Tail outlet/side outlet |
Tail outlet/side outlet |
Tail outlet/side outlet |
Tail outlet/side outlet |
Tail outlet/side outlet |
Tail outlet/side outlet |
Tail outlet/side outlet |
Tail outlet/side outlet |
Tail outlet/side outlet |
Walking lifespan |
50 million round trips/5000 km |
50 million round trips/5000 km |
50 million round trips/5000 km |
50 million round trips/5000 km |
50 million round trips/5000 km |
50 million round trips/5000 km |
50 million round trips/5000 km |
50 million round trips/5000 km |
50 million round trips/5000 km |
Rated voltage V |
DC 24V ±10% |
DC 24V ±10% |
DC 24V ±10% |
DC 24V ±10% |
DC 24V ±10% |
DC 24V ±10% |
DC 24V ±10% |
DC 24V ±10% |
DC 24V ±10% |
Rated current A |
1.5A |
1.5A |
1.5A |
1.5A |
1.5A |
1.5A |
1.5A |
1.5A |
1.5A |
Peak current A |
3A |
3A |
3A |
3A |
3A |
3A |
3A |
3A |
3A |
Rated power W |
20W |
20W |
20W |
20W |
20W |
20W |
20W |
20W |
20W |
Motor type |
DC servo motor |
DC servo motor |
DC servo motor |
DC servo motor |
DC servo motor |
DC servo motor |
DC servo motor |
DC servo motor |
DC servo motor |
Static allowable load torque Mx |
32N·m |
32N·m |
32N·m |
32N·m |
32N·m |
32N·m |
32N·m |
32N·m |
32N·m |
Static allowable load torque My |
20N·m |
20N·m |
20N·m |
20N·m |
20N·m |
20N·m |
20N·m |
20N·m |
20N·m |
Static allowable load torque Mz |
23N·m |
23N·m |
23N·m |
23N·m |
23N·m |
23N·m |
23N·m |
23N·m |
23N·m |
Dynamic allowable load torque Mx |
12.5N·m |
12.5N·m |
12.5N·m |
12.5N·m |
12.5N·m |
12.5N·m |
12.5N·m |
12.5N·m |
12.5N·m |
Dynamic allowable load torque My |
10N·m |
10N·m |
10N·m |
10N·m |
10N·m |
10N·m |
10N·m |
10N·m |
10N·m |
Dynamic allowable load torque Mz |
10N·m |
10N·m |
10N·m |
10N·m |
10N·m |
10N·m |
10N·m |
10N·m |
10N·m |
Protection level |
IP40 |
IP40 |
IP40 |
IP40 |
IP40 |
IP40 |
IP40 |
IP40 |
IP40 |
Compliant with international standards |
CE,FCC,RoHS |
CE,FCC,RoHS |
CE,FCC,RoHS |
CE,FCC,RoHS |
CE,FCC,RoHS |
CE,FCC,RoHS |
CE,FCC,RoHS |
CE,FCC,RoHS |
CE,FCC,RoHS |
Installation method |
Horizontal installation, vertical installation, side standing installation, suspended ceiling installation |
Horizontal installation, vertical installation, side standing installation, suspended ceiling installation |
Horizontal installation, vertical installation, side standing installation, suspended ceiling installation |
Horizontal installation, vertical installation, side standing installation, suspended ceiling installation |
Horizontal installation, vertical installation, side standing installation, suspended ceiling installation |
Horizontal installation, vertical installation, side standing installation, suspended ceiling installation |
Horizontal installation, vertical installation, side standing installation, suspended ceiling installation |
Horizontal installation, vertical installation, side standing installation, suspended ceiling installation |
Horizontal installation, vertical installation, side standing installation, suspended ceiling installation |